您的当前位置:首页正文

EPON相关技术及操作资料汇总(2010年1月版)

2024-10-18 来源:威能网
目录

设备相关操作 ................................................................................................................................... 3

一、15/16ONU配置双层管理vlan命令 ............................................................................... 3 二、组播业务时OLT修改查询等待时间命令...................................................................... 3 三、关闭ONU地址学习操作方法 ........................................................................................ 3 四、04/05ONU高科IAD T38传真模式修改命令 .................................................................. 4 五、 配置脚本转换时端口占用的问题 .................................................................................. 4 六、XA32盘常用故障检查命令 ............................................................................................ 5 七、XA32盘升级注意事项 .................................................................................................... 5 八、传真定位及处理方法 ....................................................................................................... 6 九、15/16onu的数据业务模版建议 ....................................................................................... 7 十、RTP流中查看电话号码方法 ........................................................................................... 8 十一、OLT判断环回的方法 ................................................................................................ 10 十二、检查ONU长发光方法 .............................................................................................. 12 十三、静音压缩在报文中的查看方法 ................................................................................. 12 十四、网卡修改流控方法 ..................................................................................................... 13 十五、ec2盘恢复驱动命令 .................................................................................................. 15 十六、普天IAD恢复出厂默认配置命令 ............................................................................ 15 十七、5006-15/16更改ICMP的优先级命令 ...................................................................... 15 十八、5006-07镜像命令 ...................................................................................................... 16 十九、5116-02将槽位信息镜像至上联口命令 ................................................................... 16 二十、5006-15/16的AC16的ping命令设置 ..................................................................... 17 二十一、MTU值的修改命令 ............................................................................................... 17 二十二、嗥鸣音超时处理命令 ............................................................................................. 17 二十三、5006-07检测语音端口事件打印命令及打印详解 ............................................... 18 二十四、各种ONU捕获信令打印命令 .............................................................................. 21 二十五、网管升级ONU的firmware方法 .......................................................................... 22 二十六、查看EC2盘获取配置命令 .................................................................................... 26 二十七、更改ec2盘支持最大距离的命令 ......................................................................... 26 二十八、EC2盘查看学习mac地址的命令 ........................................................................ 27 二十九、EC2盘查看下挂ONU的端口统计 ...................................................................... 27 三十、AN5006-15/16定时保存命令 .................................................................................... 28 三十一、网管上配置5006-20静态路由方法 ...................................................................... 29 网管相关操作 ................................................................................................................................. 32

一、网管自动升级ONU操作说明 ...................................................................................... 32 二、信令跟踪操作方法 ......................................................................................................... 32 三、网管相关服务及ini文件说明 ....................................................................................... 32 四、服务器网管恢复默认密码方法 ..................................................................................... 33 五、网管自动锁定/注销时间设置 ........................................................................................ 34 六、服务异常处理方法 ......................................................................................................... 35 七、anm2000网管配置自动备份及手动恢复备份方法 ..................................................... 36 八、服务器与客户端连接有IP转换时的特殊配置 ........................................................... 41 九、网管服务器informix,anm2000的密码修改步骤 ...................................................... 41 其他 ................................................................................................................................................ 44

一、电脑无法抓到数据VLAN信息处理方法 .................................................................... 44

设备相关操作

一、15/16ONU配置双层管理vlan命令

在15/16命令行:

cd vlan 进入vlan目录:

Admin\\vlan#set stacking manage vlan inputport [svlan id] [cvlan id] [uplik port ] [tag|untag]

其中Svlan id为外层VLAN ID 。Cvlan id为内层VLAN ID.

二、组播业务时OLT修改查询等待时间命令

GSWC主控盘命令行igmp目录下: Set igmp parameters last_query_interval 3

三、关闭ONU地址学习操作方法

可以使用图形网管如下图:

上图“0”表示ONU不学习地址,数据直接转发。

四、04/05ONU高科IAD T38传真模式修改命令

登陆至ONU:

set dsp ,选择T.38传真模式时用( 0-Huawei ,1-other ) .其他的选项不改直接回车。 修改后:save 最后一步:reset

五、 配置脚本转换时端口占用的问题

现象描述:

设备非QinQ的软件版本升级到QinQ软件版本后对于原有的单层vlan配置需要调用“Admin(DEBUG_H)> set old_config2qinq all”命令进行配置适配,该命令执行后会将所有原有的单层vlan配置转换成QINQ的内层vlan配置。转换完成保存重启后发现后8个槽位的FE端口配置在网管上有可能会无法读取,线卡上也没有这些端口的配置,但GSWC上配置并没有丢失。

原因说明:

软件中存在一个bug,在处理FE端口占用信息时传递参数传成了新槽位号(1-8,11-18),所以导致后8个槽位的端口占用信息处理错误。

解决办法:

如果待升级设备的原有GSWC软件版本为R1.21.03.34(2007.11.28)以及以后的版本,则升级时没有上述问题;

如果待升级设备的原有GSWC软件版本为R1.21.03.34(2007.11.28)以前的版本,则请记录后8个槽位的端口配置情况,执行完配置转换命令后,在debug模式下对后8槽位凡是端口业务数不为0的端口执行以下命令:

“set epon slot <1-18> onu port flag 2 reserve”。全部补齐后保存重启系统。

六、XA32盘常用故障检查命令

$get vlan static 查询线卡vlan配置是否线卡生效,和主控vlan配置信息对比

$get bridge forwording 查询线卡地址转发表,和主控fdb对比 00:17:31:1C:83:2C 7 4000 Learned 上行 00:17:31:7F:13:F8 225 4000 Learned 下行

七、XA32盘升级注意事项

升级4个文件次序最好由大到小

(CP.bin.gzDP.bin.gzdsl_10_330000003C00000D.bin.gzFD.cfg),保证成功率,升级后重启前需查询是否软件已正常写入xa32盘flash中。 注意:四个升级文件中,名字要与原文件名一致,不要修改文件名。 wri/be2000登录XA32+ $list 查询flash中软件版本信息 Flash size : 4194304 Flash Block size : 131072 Free Blocks in Flash : 1 Number of Compact Blocks :0 Page Size :4096 Number of Free Pages :0 /nvram/bin/control/ Name : CP.bin.gz

Version : 1 Size(bytes) : 2148340

//3.26版本cp文件大小,升级3.24后确认为此大小后在作重启,否则会单盘会down掉或未升级成功

Time : Sun Jan 04 11:54:15 1970 //时间1

Permission : RW State : active 必须为激活状态 Used Blocks : 17 /nvram/bin/dataplane/ Name : DP.bin.gz

Version : 1 Size(bytes) : 388504 Time : Sun Jan 04 11:56:14 1970 //时间2 Permission : RW State : active Used Blocks : 3 /nvram/bin/dslphy/

Name : dsl_10_330000003C00000D.bin.gz Version : 1 Size(bytes) : 265216 Time : Sun Jan 04 11:56:57 1970 //时间3 Permission : RW State : active Used Blocks : 3 /nvram/cfg/factorydef/ Name : FD.cfg

Version : 1 Size(bytes) : 16566 Time : Sun Jan 04 11:57:26 1970 //时间4 Permission : RW State : active

//以上关键4个文件重点核对大小、状态和时间(时间1-4为升级间隔时间,同一时间升级应间隔不多)

Used Blocks : 1 /nvram/cfg/manuf/ Name : Manuf.txt

Version : 1 Size(bytes) : 6623 Time : Wed Sep 10 09:13:21 2008 Permission : RW State : active Used Blocks : 1 /nvram/system/ Name : CFG1

Version : 0 Size(bytes) : 262032 Time :

Permission : SYS State : active Used Blocks : 2

八、传真定位及处理方法

Fttx传真问题定位及处理办法.doc

九、15/16onu的数据业务模版建议

1、6M限速模板:

(1)进入Profile目录,创建名为”adsl2+6m”的ADSL模板; Admin\\vlan# cd profile

Admin\\profile# add xaplus profile adsl2+6m //模板取名

(2)配置该ADSL模板,将下行调整为6Mbps,上行保持640Kbps不变;

Admin\\profile(XA32Plus)# downstream max interleavedelay 4 //设置下行交织深度为4 Admin\\profile(XA32Plus)# downstream max linerate 6016 //设置下行速率为6016 Admin\\profile(XA32Plus)# lineCoding gDMT //下行速率小于8Mbps时,配置成gDMT模式

Admin\\profile(XA32Plus)# upstream max interleavedelay 4 //设置上行交织深度为4 Admin\\profile(XA32Plus)# upstream max linerate 640 //设置上行速率为640 Admin\\profile(XA32Plus)#pvc 0 enable Admin\\profile(XA32Plus)#pvc 1 enable Admin\\profile(XA32Plus)#pvc 2 enable Admin\\profile(XA32Plus)#pvc 3 enable

Admin\\profile(XA32 Plus)# pvc 0 vpi A vci B (设置pvc0的vpi vci)(普通业务) Admin\\profile(XA32Plus)# pvc 1 vpi A vci B (设置pvc1的vpi vci)(家庭网关网管) Admin\\profile(XA32Plus)# pvc 2 vpi A vci B (设置pvc2的vpi vci)(宽频空间点播业务) Admin\\profile(XA32Plus)# pvc 3 vpi A vci B (设置pvc3的vpi vci)(点对点视频业务) Admin\\profile(XA32Plus)# multicast_pvc 2 设置组播业务的pvc Admin\\profile(XA32Plus)#exit

若端口模板修改,需要进行一次刷新 Admin\\profile# flush dsl-profile adsl2+6m

(3)将模板应用于端口(与端口绑定)。

Admin\\profile# set port 1:1-1:32 attach dsl-profile adsl2+6m Admin\\profile# set port 2:1-2:32 attach dsl-profile adsl2+6m „„„„

Admin\\profile# set port 8:1-8:32 attach dsl-profile adsl2+6m Admin\\profile# set port 11:1-11:32 attach dsl-profile adsl2+6m „„„„

Admin\\profile# set port 18:1-18:32 attach dsl-profile adsl2+6m

2、12M限速模板:

(1)进入Profile目录,创建名为”adsl2+12m”的ADSL模板; Admin\\vlan# cd profile

Admin\\profile# add xaplus profile adsl2+12m //模板取名

(2)配置该ADSL模板,将下行调整为12Mbps,上行保持640Kbps不变;

Admin\\profile(XA32Plus)# downstream max interleavedelay 4 //设置下行交织深度为4 Admin\\profile(XA32Plus)# downstream max linerate 12032 //设置下行速率为12032

Admin\\profile(XA32Plus)# lineCoding adsl2PlusAuto //下行速率大于8Mbps时,配置成adsl2PlusAuto模式

Admin\\profile(XA32Plus)# upstream max interleavedelay 4 //设置上行交织深度为4 Admin\\profile(XA32Plus)# upstream max linerate 640 //设置上行速率为640 Admin\\profile(XA32Plus)#pvc 0 enable Admin\\profile(XA32Plus)#pvc 1 enable Admin\\profile(XA32 Plus)#pvc 2 enable Admin\\profile(XA32 Plus)#pvc 3 enable

Admin\\profile(XA32Plus)# pvc 0 vpi A vci B (设置pvc0的vpi vci)(普通业务) Admin\\profile(XA32Plus)# pvc 1 vpi A vci B (设置pvc1的vpi vci)(家庭网关网管) Admin\\profile(XA32Plus)# pvc 2 vpi A vci B (设置pvc2的vpi vci)(宽频空间点播业务) Admin\\profile(XA32Plus)# pvc 3 vpi A vci B (设置pvc3的vpi vci)(点对点视频业务) Admin\\profile(XA32Plus)# multicast_pvc 2 设置组播业务的pvc Admin\\profile(XA32Plus)#exit

若端口模板修改,需要进行一次刷新 Admin\\profile# flush dsl-profile adsl2+12m

(3)将模板应用于端口(与端口绑定)。

Admin\\profile# set port 1:1-1:32 attach dsl-profile adsl2+12m Admin\\profile# set port 2:1-2:32 attach dsl-profile adsl2+12m „„„„

Admin\\profile# set port 8:1-8:32 attach dsl-profile adsl2+12m Admin\\profile# set port 11:1-11:32 attach dsl-profile adsl2+12m „„„„

Admin\\profile# set port 18:1-18:32 attach dsl-profile adsl2+12m

注:(1) 具体开通业务和VPI/VCI请根据当地情况配置。

(2) 上、下行交织深度参数与当地线路情况关系较大,若在实际使用中有线路不稳定情况,请酌情增加交织深度到8或者16。

十、RTP流中查看电话号码方法

1、什么是DTMF口气频率? DTMF双音多频率主张.

DTMF音调,当你听到你的声音对新闻界主要标准电话键盘. 基调是每个按钮的专栏,连续调总和. 这就是它被称为\"双调\"

DTMF频率 1209hz 1336hz 1477hz 1633hz 2 5 8 0 3 6 9 # A B C D 697hz 1 770hz 4 852hz 7 941hz *

2、 查看rtp流中的拨号方法: 1)存出iad上行的rtp流文件;

2)用cooledit打开上面存出的文件(此软件可以网上下载); 3)选择菜单“view”----“spectral view”,或者选择快捷按钮“Toggle Between Spectral and Waveform”,如下图:

4)波形转换后图形如下:

5)上面显示的亮点表示频率,每一个号码都是两个频率组成,具体频率与号码对应关系见上面的dtmf标准; 6) 查看每个号码具体频率可以选中具体号码范围,再选中菜单“analyze”----“show frequence analysis”,如下图:

按照以上方法可以看到每个拨号的频率,判断故障时可以把波形中的频率和标准频率对比即可。如果波形中一个号码出现三个甚至四个频率或者亮点,则是话机上报有问题。

十一、OLT判断环回的方法

查看GSWC盘交换芯片端口的mac地址:

1、询问上联口对接交换机或者BRAS之类的mac地址; 2、观察芯片0和芯片1的mac地址表的命令:

Admin(DEBUG_H)> show l2 entry 0 vid 58 //查看芯片0的命令,58为vlanid Admin(DEBUG_H)> show l2 entry 1 vid 58 //查看芯片1的命令,58为vlanid 交换芯片端口号对照表如下:

新槽位 1 2 3 老槽位 1 2 3 芯片号 0 0 0 端口号 7 6 5 4 5 6 7 8 11 12 13 14 15 16 17 18 19(ac16) 上联口 29 29 29 29 29 29 29 4 5 6 7 8 9 10 11 12 13 14 15 16 17 0 0 0 0 0 1 1 1 1 0 0 0 0 1 4 3 2 1 0 3 2 1 0 11 10 9 8 4 芯片号 1 2 3 4 5 6 7 1 1 1 1 1 1 1 端口号 5 6 7 8 9 10 11 3、观察交换芯片端口学习的mac地址在通和不通时学习情况是否正确。主要是观察mac地址是否始终学习在正确的端口上,如果发现ec2盘槽位学习到了上联设备的mac地址,则表示该槽位有环回问题。

十二、检查ONU长发光方法

登录进ec2盘的pon目录,输入 show onu discover

此命令可以看到onu的注册信息,如果发现onu在没有掉电的情况下注册信息不断的变化,则可能有onu在长发光。

十三、静音压缩在报文中的查看方法

1、 在wireshark中用rtp过滤抓包; 2、 选择源ip为我们iad的报文,然后点击菜单“statistics”—〉“rtp”----〉“stream analysis”; 3、 在rtp分析窗口中查看“marker”项,如下图:

如果在“marker”这一列存在“set”,则说明iad的静音压缩打开了。

在传真问题处理时,可以用以上方法查看静音压缩是否打开,如果发现是打开的,则在网管上关闭此项。

十四、网卡修改流控方法

当5006-03/04/07/09/10的ONU需要采用上行限速功能时,需要打开ONU和ONU对接设备的流控功能,ONU的流控在网管上直接打开就行了,ONU对接的设备如果为电脑则按照以下方法打开流控功能。

1、 打开网卡属性界面,点击“属性”按钮,打开网卡属性界面:

2、 在属性窗口中点击“配置”按钮,如下图:

3、在网卡的配置窗口中选择“高级”,然后选择“流程控制”(有的网卡显示英文为”flow control”)。 在“流程控制”的右边“值”中选择“生成和响应”(有的网卡显示英文为”RX/TX PAUSE”),即收发都启用流控功能。

4、个别网卡需要设置一个特殊项“中断节流率”( Interrupt Throttle Rate),如下图:

中断节流率的默认设置为“适应性”,在使用流控功能时,需要把中断节流率设置为“关”。

十五、ec2盘恢复驱动命令

GSWC和EC2盘主从通信出现丢包时,需要复位EC2盘的底层驱动,命令如下: 1、登陆至EC2下;

2、在DEBUG目录下:set motdriv 恢复驱动芯片,而不用拔盘复位; 后期将通过升级EC2盘软件解决。

十六、普天IAD恢复出厂默认配置命令

system目录下面,输入load df1,再保存save,然后重启。

十七、5006-15/16更改ICMP的优先级命令

1、fswb盘在pppoe封装时修改icmp优先级命令 debug目录下

单层VLAN模式下修改pppoe封装的ICMP报文优先级 create filter indexid 1

set filter indexid 1 param offset 32 data 0x01 mask 0xff set filter indexid 1 action newpri data 7 set filter indexid 1 attach port 29:4

双层VLAN模式下修改pppoe封装的ICMP报文优先级 create filter indexid 1

set filter indexid 1 param offset 36 data 0x01 mask 0xff set filter indexid 1 action newpri data 7 set filter indexid 1 attach port 29:4

取消修改

delete filter indexid 1

2、主控盘FSWB没有pppoe封装时设置icmp包优先级配置命令如下: create qos access_profile icmp

set qos access_profile icmp parameter protocoltype 0x01 set qos access_profile icmp action newpriority 7 set uplink port 29:4 attach qos access_profile icmp

3、5006-15没有pppoe封装时提高icmp包优先级的线卡配置命令如下 telnet到线卡:

$create filter rule entry ruleid 31 action retagprio priority 7 $create filter subrule icmp ruleid 31 subruleid 1

$create filter rule map ifname eth-0 ruleid 31 stageid 1 $modify filter rule entry ruleid 31 status enable

现场根据是否有pppoe封装来输入不同的命令,在没有pppoe封装时只需要输入第2、3组命令中的一组命令就可以了。

十八、5006-07镜像命令

Config\\igmp# set igmp disable Set igmp disable OK! Config\\switch# sh arl

Arl Table-mac:08:00:3e:03:02:02:--port:26vlan:4087: Arl Table-mac:00:0a:c2:11:0f:c3:--port:25vlan: 10: Arl Table-mac:54:4b:37:21:00:00:--port:26vlan:4088: Arl Table-mac:00:1e:c9:cc:c3:ea:--port: 2vlan:4088: Arl Table-mac:00:0a:88:88:88:07:--port:26vlan:4089: Arl Table-mac:00:0a:c2:11:0f:c3:--port:25vlan:4089: Arl Table-mac:02:ff:bb:73:f9:ad:--port:26vlan: 10: Arl Table-mac:00:0a:c2:11:0f:c3:--port:25vlan:4087: Config\\switch# set mirror enable

Config\\switch# SET mirror ingress port 26 return OK!

Config\\switch# SET mirror egress port 26 return OK!

Config\\switch# SET mirror ingress port 25 return OK!

Config\\switch# SET mirror egress port 25 return OK!

Config\\switch# set mirror capture port 2 return OK!

Config\\switch# set mirror capture port 2 return OK!

做以上命令的同时需要在网管上打开端口2,即端口2的占用应该打勾。

十九、5116-02将槽位信息镜像至上联口命令

进入GSWC的debug状态下,输入以下命令:

Admin(DEBUG_H)> set uplink mirror slot /*设置镜像*/ Admin(DEBUG_H)> set slot mirror disable /*关闭镜像*/

二十、5006-15/16的AC16的ping命令设置

5006-15/16升级为930软件后,AC16中的ping命令和原来不同,特此说明: 1、 设置ping,telnet到AC16内输入如下命令: [Fiberhome CONSOLE]>ping

Please input ping destionation ip address :

10.69.132.108 //设置ping的目的IP number of packets to send (0:this routine runs continuously): 3 //设置ping的次数 len of the ICMP packet (default 64) :

//设置ICMP的包长,默认为64字节 interval in seconds (default 1 second) :

//设置ICMP包间隔,默认为1s timeout in seconds (default 5 seconds) :

//设置超时时间,默认为5 2、 在AC16中输入重定向命令: [Fiberhome CONSOLE]>settelnet

telnet redirect to telnet(No) (\"Y\" or \"N\"):Y //选择Y

telnet redirect type(1) (\"1:Redirect primary\" or \"2:Redirect all\"):2 //选择2 需要采用ping功能时,必须设置重定向命令,且必须按照以上选择设置。 3、 退出AC16的telnet

[Fiberhome CONSOLE]>telnetquit

4、 再次telnet到AC16,将自动执行重定向命令,即自动开始ping目的IP。按照设置的次

数ping完后将自动结束

5、 如果要关闭重定向功能,则在第二步中选择“N”即可。如果在前面设置ping的次数时

选择的0,则telnet到AC16时会不停的ping,此时退出需要盲打命令。

二十一、MTU值的修改命令

在GSWC盘内输入lll进入DEBUG模式:

set max framelength 1536 //1536即为MTU值,可根据需要修改此值

二十二、嗥鸣音超时处理命令

1、07命令行设置命令:

Config\\protocol# set roh auto_play enable timeout_release enable timeout_setoutofsv enable

显示命令

Config\\protocol# show roh

auto play roh :enable //当MGC忙音超时之后没有下发嗥鸣音时,设备是否自己放嗥鸣音

release user when roh timeout :enable //嗥鸣音超时之后是否发注销命令

set user out of service when roh timeout :enable //嗥鸣音超时之后是否设置状态为OutOfService

2、15命令行设置

[Fiberhome CONSOLE]>setroh

auto play roh when bt timeout?(Y/N) [Y] :Y release user when roh timeout?(Y/N) [N] :Y

set termstate is outofservice when roh timeout?(Y/N) [N] :Y

二十三、5006-07检测语音端口事件打印命令及打印详解

1、设置命令如下:

Config\\protocol# set debug port 接下来若输入<1-16> /input vaild port num/ 输入 all /debug all ports/ 输入 none /don‘t debug any ports/ 2、打印内容详解如下:

1/-1:Detect event:port=1 cmd =0x21 端口1摘机

1/2:fttbOpenChannel....rtpmode=3,ssrcflag=1 端口1打开通道 1/2:fttbFaxSet....mode = 0 设置传真模式为透传

1/2:fttbPlayCallProgressTone....port=1,type=1,times=255, dialTiming=0 放拨号音 1/2:Detect event:port=1 cmd =0x0 号码0 1/2:fttbStopCallProgressTone.... 停拨号音 1/2:Detect event:port=1 cmd =0x3 号码3 1/2:Detect event:port=1 cmd =0x7 号码7 1/2:Detect event:port=1 cmd =0x1 号码1 1/2:Detect event:port=1 cmd =0x6 号码6 1/2:Detect event:port=1 cmd =0x5 号码5 1/2:Detect event:port=1 cmd =0x6 号码6 1/2:Detect event:port=1 cmd =0x5 号码5 1/2:Detect event:port=1 cmd =0x5 号码5 1/2:Detect event:port=1 cmd =0x6 号码6 1/2:Detect event:port=1 cmd =0x3 号码3 1/2:Detect event:port=1 cmd =0x7 号码7

1/2:fttbChanSocketInitial....lport=20000,lip=de586883 初始化本地Socket,端口号为20000,本地IP为0xde586883

1/2:fttbSetJitter...jit = 40. 设置抖动缓存为40

1/2:fttbSetEC...mode = 1. 设置回声抑制(Echo Control)为1(Enable) 1/2:fttbSetSCE....value = 1 设置静音压缩(Silence Compresion Control)为

1(Enable)

1/2:tSID....mode = 1 设置舒适噪音(Soft Noise)为1(Enable) 1/2:fttbVoiceVolumeControl....InputGain = 0, outputGain=0 设置输入输出增益为0db 1/2:fttbSetVoiceCoder...codec = 0. 设置语音编码方式为0(PCMA),这里设置Coder的值和SDP带的值不相同

1/2:fttbSetRTPPacketInterval...interval = 3. 设置发送包间隔为3(20ms) 1/2:fttbRtpControl...mode = 2. 设置收发模式为2(Recv Only)

1/2:fttbDTMFTransMode....mode = 2 设置二次拨号方式为2(Transparent)

1/2:fttbRtpControl...mode = 3. 设置收发模式为3(Unactive)

1/2:fttbCloseSocket.... 关闭本地Socket

1/2:fttbChanSocketInitial....lport=20000,lip=de586883 初始化本地Socket,端口号为20000,本地IP为0xde586883

1/2:fttbChanSocketBindRemoteAddr....rport=14092,rip=a078883 绑定远端地址,端口号为14092,远端IP为0xa078883

1/2:fttbFaxSet....mode = 0 设置传真模式为透传 1/2:fttbSetVoiceCoder...codec = 0. 设置语音编码方式为0(PCMA)

1/2:fttbSetRTPPacketInterval...interval = 3. 设置发送包间隔为3(20ms) 1/2:fttbRtpControl...mode = 2. 设置收发模式为2(Recv Only)

1/2:fttbRtpControl...mode = 0. 设置收发模式为0(SendRecv)

1/2:ProcessPole....mode = 1 反极

1/2:Detect event:port=1 cmd =0x37 检测到ANSAM

0x160a968 (Poll_Receive): Enter EnableVBDMode status is 0 DSP的打印,检测到传真事件,切换到VBD模式,但VBD状态为Disable

1/2:fttbSetJitterAll...jitMin = 0x64, jitOptFactor = 0xd, jitMax = 0x64. 设置抖动缓存为100,固定Buffer

1/2:fttbSetECAll...mode = 0x0 nlpmode = 0x1 eclength = 0x7. 关闭回声抑制和NLP

1/2:fttbSetSCE....value = 0 设置静音压缩(Silence Compresion Control)为0(Disable)

1/2:tSID....mode = 0 设置舒适噪音(Soft Noise)为0(Disable)

1/2:Detect event:port=1 cmd =0x4a 检测到PT96,也就是对方发过来的RTP带冗余

1/2:fttbSetRTPPacketInterval...interval = 2. 设置发送包间隔为2(10ms) 0x160a968 (Poll_Receive): Enter EnableVBDMode status is 0 DSP的打印,检测到传真事件,切换到VBD模式,但VBD状态为Disable

0x160a968 (Poll_Receive): Enter EnableVBDMode status is 0 DSP的打印,检测到传真事件,切换到VBD模式,但VBD状态为Disable

0x13cb3d8 (Timer Mgr): port 1:recvd ANSAM event! 协议栈打印,收到ANSAM

0x160a968 (Poll_Receive): Enter EnableVBDMode status is 0 DSP的打印,检测到传真事件,切换到VBD模式,但VBD状态为Disable

0x160a968 (Poll_Receive): Enter EnableVBDMode status is 0 DSP的打印,检测到传真事件,切换到VBD模式,但VBD状态为Disable

0x160a968 (Poll_Receive): Enter EnableVBDMode status is 0 DSP的打印,检测到传真事件,切换到VBD模式,但VBD状态为Disable

0x160a968 (Poll_Receive): Enter EnableVBDMode status is 0 DSP的打印,检测到传真事件,切换到VBD模式,但VBD状态为Disable

0x160a968 (Poll_Receive): Enter EnableVBDMode status is 0 DSP的打印,检测到传真事件,切换到VBD模式,但VBD状态为Disable

0x160a968 (Poll_Receive): Enter EnableVBDMode status is 0 DSP的打印,检测到传真事件,切换到VBD模式,但VBD状态为Disable

0x160a968 (Poll_Receive): Enter EnableVBDMode status is 0 DSP的打印,检测到传真事件,切换到VBD模式,但VBD状态为Disable

DSP不是所有的传真事件都上报给上层协议栈,所以看到DSP有很多打印,上层协议栈并没有收到对应的传真事件

1/2:Detect event:port=1 cmd =0x32 检测到传真事件V21 0x160a968 (Poll_Receive): Enter EnableVBDMode status is 0 DSP的打印,检测到传真事件,切换到VBD模式,但VBD状态为Disable

1/2:fttbSetJitterAll...jitMin = 0x64, jitOptFactor = 0xd, jitMax = 0x64. 设置抖动缓存为100,固定Buffer

1/2:fttbSetECAll...mode = 0x1 nlpmode = 0x1 eclength = 0x7. 关闭回声抑制和NLP

1/2:fttbSetSCE....value = 0 设置静音压缩(Silence Compresion Control)为0(Disable)

1/2:tSID....mode = 0 设置舒适噪音(Soft Noise)为0(Disable)

0x15417a0 (EPP Client): port 1:recvd fax V21F event! 上层协议栈打印,收到传真事件V21

1/2:Detect event:port=1 cmd =0x49 检测到对方切换到T38

0x15417a0 (EPP Client): go to t38!!! 上层协议栈打印,切换到T38

1/2:fttbRtpControl...mode = 3. 设置收发模式为3(Unactive)

1/2:fttbCloseSocket.... 关闭Socket

1/2:fttbT38SocketInitial....lport=20000,lip=de586883 初始化本地T38 Socket,端口号为20000,本地IP为0xde586883

1/2:fttbT38SocketBindRemoteAddr....rport=14092,rip=a078883 绑定远端地址到T38 Socket,端口号为14092,远端IP为0xa078883

1/2:fttbFaxSet....mode = 1 传真模式设置为1(Relay),也就是T38

1/2:fttbSetRTPPacketInterval...interval = 2. 设置发送包间隔为2(10ms)

1/2:fttbRtpControl...mode = 0. 设置收发模式为0(SendRecv)

0x160a968 (Poll_Receive): Enter EnableVBDMode status is 0 DSP的打印,检测到传真事件,切换到VBD模式,但VBD状态为Disable

1/2:ProcessPole....mode = 0 设置反极

1/2:fttbPlayCallProgressTone....port=1,type=3,times=255, dialTiming=0 1/2:fttbStopCallProgressTone.... 1/2:fttbPlayCallProgressTone....port=1,type=6,times=255, dialTiming=0 1/2:Detect event:port=1 cmd =0x20 1/2:fttbSetJitterAll...jitMin = 0x28, jitOptFactor = 0x7, jitMax = 0x28. 40ms,优化选项为7

1/2:fttbSetECAll...mode = 0x1 nlpmode = 0x0 eclength = 0x7. 1/2:fttbSetSCE....value = 1 抑制

1/2:fttbStopCallProgressTone.... 1/2:fttbGetRTPStatics.... 信息

1/2:fttbGetRTPStatics.... 信息,搞了两次,应该有问题,但不影响

1/2:fttbRtpControl...mode = 3. 模式为3(Unactive)

1/2:fttbCloseSocket.... Socket

1/2:r fttbCloseChannel....

二十四、各种ONU捕获信令打印命令

1、高科IAD:

MG6002(F2)$set debug megaco

->是否输出fatal信息? 'yes' or 'no'[yes]: ->是否输出error信息? 'yes' or 'no'[yes]: ->是否输出warning信息? 'yes' or 'no'[no]: ->是否输出send信息? 'yes' or 'no'[no]: yes ->是否输出receive信息? 'yes' or 'no'[no]: yes ->是否输出information信息? 'yes' or 'no'[no]:

确定更改配置吗? 'yes' or 'no'[no]: y

忙音

停音 警告音

挂机 还原抖动缓存为 开启EC 开启静音 停音

获取统计 获取统计 设置收发 关闭 关闭通道 2、5006-07ONU:

Config\\protocol# set debug_level <1-9> 1 . RV_LOGMASK_ALL

2 . RV_LOGMASK_NONE /关闭调试信息选此项/ 3 . RV_LOGLEVEL_FATAL

4 . RV_LOGLEVEL_ERROR * /带“*”表示已选择打开项/ 5 . RV_LOGLEVEL_WARNING

6 . RV_LOGLEVEL_SEND * 7 . RV_LOGLEVEL_RECEIVE * 8 . RV_LOGLEVEL_ENTER 9 . RV_LOGLEVEL_LEAVE

说明:查看此类调试信息时,通常为了快速定位,只打开6,7调试,其他不需打开。

3、5006-15/16ONU:

[Fiberhome CONSOLE]> SetDebugLevel (内容选择同07设备) Please input debug level value(1~9):6 Continue to set the debug level?[Yes|No]y Please input debug level value(1~9):7 Continue to set the debug level?[Yes|No]y

4、普天IAD:

在system>路径下输入相关命令,具体使用如下:

system> debug call 2 (输入调试命令) Set debug level of \"Call Control\" OK.

system> debug start (启动进入调试状态)

Debugging has been started. (Ctrl-C to quit) 注:退出调试状态,输入Ctrl+C键

二十五、网管升级ONU的firmware方法

1、 编辑pers文件方法

针对不同类型的ONU提供了不同的*.tkp模板文件和*.tkf升级文件,我们可以使用tkPersEditor.exe软件,根据这两个归档文件编辑出用于下载的ONU personality文件。 1) 第一次使用时,打开tkPersEditor.exe软件,单击”File”菜单,选择“New”,然后载入该类ONU归档的*.tkp文件。载入时应根据该ONU的类型选择相应文件。 2) 单击”File”菜单,选择“Open”,然后载入该类ONU归档的*.tkf文件。载入时应根据该ONU的类型选择相应文件。

3) 在左边栏目中分别选择”Base MAC Address of EPON Port”和” Base MAC Address of User Ports”,在右边栏目中编辑为该ONU实际的MAC地址。例图如下:

4) 点击上图中左边第一行”Extended Vendor ID Information”,编辑ONU的类型值,ONU的类型取值规定参考后面的附件表格(附件表格中没有的ONU不需要编辑此项)。 5) 编辑完ONU的MAC地址和类型值之后,单击”File”菜单,选择“Save TKF As”,然后指定要保存的文件目录,如根据上述步骤中,应选择D:\\ , 文件名更改为onu_pers.tkf即可。 6) 如果继续编辑同类型的其他ONU的pers,可不关闭上诉窗口,直接重复步骤3和步骤4即可。

附件:编辑ONU的类型值 ONU类型 设备型号 WKE2134219A1A WKE2134219A1AX WKE2134219A1D WKE2134219A1DX WKE2134219A2A WKE2134219A2AX WKE2134219A2D WKE2134219A2DX WKE2134219B1A. ONU自定义字段 70A1030000000000000WKE2.170.738R1B 70A1031000000000000WKE2.170.746R1B 70A1020000000000000WKE2.170.738R1B 70A1021000000000000WKE2.170.746R1B 70A2030000000000000WKE2.170.745R1B 70A2031000000000000WKE2.170.747R1B 70A2020000000000000WKE2.170.745R1B 70A2021000000000000WKE2.170.747R1B 70B1030000000000000WKE2.170.738R1B 70B1031000000000000WKE2.170.746R1B 70B1020000000000000WKE2.170.738R1B 70B1021000000000000WKE2.170.746R1B 70B2030000000000000WKE2.170.745R1B 70B2031000000000000WKE2.170.747R1B 70B2020000000000000WKE2.170.745R1B 70B2021000000000000WKE2.170.747R1B 70B1130000000000000WKE2.170.738R1B 70B1131000000000000WKE2.170.746R1B 70B1120000000000000WKE2.170.738R1B 70B1121000000000000WKE2.170.746R1B 70B2130000000000000WKE2.170.745R1B 70B2131000000000000WKE2.170.747R1B 70B2120000000000000WKE2.170.745R1B AN5006-07 WKE2134219B1AX WKE2134219B1D WKE2134219B1DX WKE2134219B2A WKE2134219B2AX WKE2134219B2D WKE2134219B2DX WKE2134219C1A WKE2134219C1AX WKE2134219C1D WKE2134219C1DX WKE2134219C2A WKE2134219C2AX WKE2134219C2D ONU类型 WKE2134219C2DX WKE2134219D1A WKE2134219D1AX WKE2134219D1D WKE2134219D1DX WKE2134219D2A WKE2134219D2AX WKE2134219D2D WKE2134219D2DX 盘号 WKE2.119.148R2A WKE2.119.149R2A 70B2121000000000000WKE2.170.747R1B 70A1130000000000000WKE2.170.738R1B 70A1131000000000000WKE2.170.746R1B 70A1120000000000000WKE2.170.738R1B 70A1121000000000000WKE2.170.746R1B 70A2130000000000000WKE2.170.745R1B 70A2131000000000000WKE2.170.747R1B 70A2120000000000000WKE2.170.745R1B 70A2121000000000000WKE2.170.747R1B ONU自定义字段 2011010000000000000WKE2.119.148r2a 2012010000000000000WKE2.119.149r2a 2021110000000000000WKE2.119.150r2a 2022110000000000000WKE2.119.151r2a 2012010000000000000WKE2.119.247r1a 2022110000000000000WKE2.119.248r1a 5011010000000000000WKE2.119.154r2a 5012010000000000000WKE2.119.155r2a 5021110000000000000WKE2.119.156r2a 5022110000000000000WKE2.119.157r2a 5012010000000000000WKE2.119.249r1a 5022110000000000000WKE2.119.250r1a ONU自定义字段 3011010000000000000WKE2.167.159r1b 3012010000000000000WKE2.167.160r1b 3021110000000000000WKE2.167.161r1b 3022110000000000000WKE2.167.162r1b 4011010000000000000WKE2.167.163r1b 4012010000000000000WKE2.167.164r1b 4021110000000000000WKE2.167.165r1b 4022110000000000000WKE2.167.166r1b ONU自定义字段 2a12010000000000000WKE2.167.152r1c AN5006-02 WKE2.119.150R2A WKE2.119.151R2A WKE2.119.247R1A WKE2.119.248R1A WKE2.119.154R2A WKE2.119.155R2A AN5006-05 WKE2.119.156R2A WKE2.119.157R2A WKE2.119.249R1A WKE2.119.250R1A ONU类型 盘号 WKE2.167.159R1B WKE2.167.160R1B WKE2.167.161R1B WKE2.167.162R1B WKE2.167.163R1B AN5006-03 AN5006-04 WKE2.167.164R1B WKE2.167.165R1B WKE2.167.166R1B 盘号 ONU类型 AN5006-02A WKE2.167.152R1C WKE2.167.154R1C AN5006-05A ONU类型 AN5006-15 (EUP2) AN5006-15_X (EUP2_X) AN5006-16 (EUP2) AN5006-16_X (EUP2_X) WKE2.167.156R1C WKE2.167.158R1C 盘号 WKE2.170.785R2B WKE2.170.793R2B WKE2.170.831R2B WKE2.170.830R2B 2a22110000000000000WKE2.167.154r1c 5a12010000000000000WKE2.167.156r1c 5a22110000000000000WKE2.167.158r1c ONU自定义字段 1512021000000000000WKE2.170.785R2B 1512020000000000000WKE2.170.793R2B 1612021000000000000WKE2.170.831R2B 1612020000000000000WKE2.170.830R2B

2、升级onu的firmware

1) 通过图形网管界面单击系统模块的GSWC盘,依次选择配置----升级系统软件,将弹出

一个对话框,首先填写对话框如下:

单击“升级软件” ,并等待升级结束,ONU的boot程序即升级完毕。

2) 将上图对话框中的“文件名”项改为onu_app.tkf,再单击“升级系统软件” ,并等待

升级结束,ONU的app程序即升级完毕。

3) 将上图对话框中的“文件名”项改为onu_pers.tkf,再单击“升级系统软件” ,并等待

升级结束,ONU的pers程序即升级完毕。 4) ONU升级完成后,应登陆到系统的命令行网管中,在该ONU所在的EC2命令行的PON

目录下执行restore onu 命令(可以升级完一个pon口所有onu后一起restore)。

5) restore执行完毕后,再通过网管重启ONU即完成firmware升级。

二十六、查看EC2盘获取配置命令

登陆到EC2盘,输入以下命令:

config\\pon#show qinq_config

//此命令用来查看ec2盘下挂onu的具体端口是否获取到vlan配置,可以看到svlan和cvlan相关配置 示例:

Config\\pon# show qinq_config 1 544b71010b30 1

onu 2 port 1 sevicenum: 1,configed:YES(2) **************service:0************** Connect to llid 0 service_type:unicast differ_rule clausenum:0

qinq_rule clausenum:2

clause 0,field-value-operator:4-0-0-0-0-3-e8-3 clause 1,field-value-operator:4-0-0-0-0-1-f4-4

svlan:1632,scos:0,cvlanmode:1,cvlan:516,ccos:0,txvlan:0,tcos:0

二十七、更改ec2盘支持最大距离的命令

登录到ec2盘,进入pon目录,命令如下: Config\\pon# SET max_distance <1-2> pon no(1-2).

Config\\pon# SET max_distance 1 20 set to 20km. 30 set to 30km. 70 set to 70km.

Config\\pon# SET max_distance 1 70 //设置检测距离为70公里 Config\\pon# show olt version <1-2> pon no(1-2).

Config\\pon# show olt version 1 //查看ec2盘检测距离 the olt_mac is: 544b37210000 the olt_IEEE ONU is: 00 0d b6 the olt_product code is: 3721 the olt_product version is: 06 00 the olt_firmware version is: 01 40

olt status version: 140 olt pon 1 present: YES olt support distance: 70

二十八、EC2盘查看学习mac地址的命令

命令原型

show macentry <1-2> 命令实例

Config\\port# show macentry 1 544b40022450 1

user port label is :544b400224500001 number of entries is :1 mac addres is :

No. 1 :00179a6899f4 标红的则为学习到的MAC地址

二十九、EC2盘查看下挂ONU的端口统计

命令原型

show port onu <1-2> [up|down] 命令实例

Config\\statis# show port onu 1 544b40022450 1 up

the port label is : 54 4b 40 02 24 50 00 01 the direction is: upstream

transmitted octets: 1-1913948501 total frames transmitted: 11017483 unicast frames transmitted: 11016123 broadcast frames transmitted: 1175 multicast frames transmitted: 185 CRC-32 error frames: 0 undersize frames: 0 oversize frames: 0 collision times: 0

64 octet frames: 4730213 64-127 octet frames: 3979299 128-255 octet frames: 950563 256-511 octet frames: 363596 512-1023 octet frames: 2311463 1024-1518 octet frames: 11262116 1519+ octet frames: 0 dropped frames with overflow: 0

dropped octets witn overflow: 0 delayed octets: 0 granted octets: 0 octets granted but unused: 0 CRC-8(preamble) errors: 0 pause frames: 0 line coding errors: 0

该命令为查看上行包统计,down则为查看下行包统计。 重点看:

CRC-32 error frames和CRC-8(preamble) errors 该项值高说明光路不稳定 1024-1518 octet frames为各项包长的统计。

在进行查看之前先清一下该onu的计数 命令原型

reset counter [olt|onu] <1-2> {}*1 命令实例

Config\\statis# reset counter onu 1 544b40022450

三十、AN5006-15/16定时保存命令

V1.2版本具备

1. 设置保存模式为每周保存

Admin\\device# set save frequency once_a_week save_time 0

配置后,即在每周与这条命令配置当天相同的星期数的零点进行保存。(如果配置时是周2,即每周2的零点进行保存)。 save_time范围:0-23(时) 2. 设置保存模式为每天保存

Admin\\device# set save frequency once_a_day save_time 14 配置后,即在每天的14点进行保存。 save_time范围:0-23(时) 3. 设置保存模式为每周期保存

Admin\\device# set save frequency once_per_cycle save_time 4 cycle 1 配置后,即从4点开始,以1小时为周期,保存。 save_time范围:0-23(时) cycle范围:1-720(小时) 配置后,在Admin目录下save。 注:上述时间请跟据需要来定。

三十一、网管上配置5006-20静态路由方法

OLT升级到V1.3版本,20ONU升级到RP0104版本,网管升级到46sp1版本后,可以在网管上配置静态路由和20ONU的管理VLAN 和管理IP ,并且要求必须在网管上配置静态路由。如果直接TELNET到20ONU在命令行中配置静态路由,当20onu断电重启后,静态路由会丢失,主要原因是20ONU升级到RP0104版本后,软件进行了修改,因此不要将语音网关配置静态路由方式。 具体配置方法如下:

1、 配置20ONU管理VLAN

1.1、是在EC2盘ONU的列表中选择20ONU, 配置如下:

1.2、配置管理vlan 和 管理IP ,管理网关配为0.0.0.0(必配) ,如下图中所示:

2、网管上配置静态路由

2.1 在EC2盘ONU的列表中选择静态路由如下:

该功能是46sp1版本具有的,46版本以下包括46版本都没有该配置选项。 2.2、在静态路由配置选项中会显示默认的静态路由表如下:

将上面的所有静态路由表删除,添加所需要的静态路由,如下图中:

上面的目的地址为网管服务器的IP地址218.7.31.195,网关为管理IP的网关172.23.170.1 。

网管相关操作

一、网管自动升级ONU操作说明

二、信令跟踪操作方法

信令跟踪可以保存,但打开只能使用ANM2000网管自身软件打开,且文件显示时间为当前打开的时间,而非保存的时间。 信令跟踪操作方法:

1、 打开OLT的SNMP TRAP功能;

示例:

Admin\\service# service snmp enable Admin\\service# service snmp trap enable

Admin\\service# set snmp trapreceiver add 10.8.8.8 version v2c community adsl 2、 在GSWC盘上点右键,选择信令跟踪开关,在窗口中填入iad ip、L4源/目的端口号(即

语音协议端口号)、使能,下载到设备; 3、在菜单上选择“配置”----“信令跟踪”,然后选择“开始”则开始跟踪

三、网管相关服务及ini文件说明

1、服务作用:

AEMS-DBServer:网管后台服务。

AEMS-RPCServer:RPC服务,用于将webservice的命令传递给网管后台服务。

AEMS-DumpServer:数据转储服务,用于将历史告警、性能从数据库转储至文本;并用于对当前告警做自动确认。

Anm2000 Daemon Service:网管的守护进程,用户防止其他服务被意外中断而引起网管故障,会自动启动网管的其他服务。

Manager for Access Net:数据采集服务。 AEMS-WebServiceServer:webservice服务。 AEMS-TL1Server:tl1服务。

另外:对于网管接口对接情况,anmws.ini文件修改(具体见ini文件说明)后,md.ini中增加一项配置控制通过接口下发命令是否同步数据库。 [ANSERVER]

;仅运行TL1接口时修改以下设置。如果删除INTERFACE_SYNCTODB_ENABLE,程序中默认设

为0,为0时不同步数据库,非0时同步数据库。如果需要自动同步数据库,必须先升级客户端,并且将INTERFACE_SYNCTODB_ENABLE设为1;如果不需要自动同步数据库,必须将INTERFACE_SYNCTODB_ENABLE删除或设为0 INTERFACE_SYNCTODB_ENABLE = 1

此外,对于ansvr.ini文件中请将BIND_TO_IP、SEND_TO_IP两项值配置为网管后台服务所用IP,即AEMS-DBServer的IP。

2、ini文件说明

四、服务器网管恢复默认密码方法

1、在笔记本电脑上安装相同版本的网管,在“D:\\AEMS\\md\\andb\\staticdata”目录下复制“anuser.unl”到服务器网管的d盘根目录下; 2、打开服务器网管informix的工具“sql editor 3.01”,选中数据库实例下的andb@ol_***,如下图范例:

3、在sql editor空白处填入命令: delete from anuser where rowid>0;

load from \"D:\\anuser.unl\" insert into anuser; 如下图:

4、点击上图中向右的小箭头,运行输入的命令即可,如下图:

按照以上操作执行后,网管密码将恢复成初始化数据库时的密码。

五、网管自动锁定/注销时间设置

打开d:\\aems\\fhanms\\ini\\aems.ini,找到文件中以下内容: [AUTOLOGIN]

;网管系统自动锁定等待时间,单位:分钟,-1表示禁止自动锁定 AUTO_LOCK_TIMEOUT = 10

;网管系统锁定后自动注销的时间间隔,分钟为单位 timespace=10

上面两项分别为自动锁定和自动注销,时间可以根据需要设置。如果不需要这两项功能,可以设置为-1即表示禁止自动锁定和自动注销。

六、服务异常处理方法

工程上若有ANM2000服务异常,请先不要重启服务,利用userdump工具采集相应信息,并第一时间通知技术支援部。

userdump工具的使用方法是:在windows命令控制台输入 userdump

例如:要导出anserver的转储文件,可以输入 userdump anserver.exe 如:

C:\\Documents and Settings\\Administrator\\桌面\ump>userdump admaems.exe User Mode Process Dumper (Version 3.0)

Copyright (c) 1999 Microsoft Corp. All rights reserved. Dumping process 6108 (admaems.exe) to

C:\\Documents and Settings\\Administrator\\Dumping process 6108 (admaems.exe) to C:\\Documents and Settings\\Administrator\\桌面\ump\\admaems.dmp... The process was dumped successfully. +++++++++++++++++++++

C:\\Documents and Settings\\Administrator\\桌面\ump>userdump ANServer.exe User Mode Process Dumper (Version 3.0)

Copyright (c) 1999 Microsoft Corp. All rights reserved. Dumping process 4804 (ANServer.exe) to

C:\\Documents and Settings\\Administrator\\Dumping process 4804 (ANServer.exe) to C:\\Documents and Settings\\Administrator\\桌面\ump\\ANServer.dmp... The process was dumped successfully.

这样在当前目录下,会生成一个*.dmp文件,把这个文件压缩打包发回来就可以进行调试了,另外注明一下程序编译时间。 注:

AEMS-DBServer对应的进程名为ANServer.exe

Manager for Access Net对应的进程名为admaems.exe

附软件:

七、anm2000网管配置自动备份及手动恢复备份方法

1. ANM2000网管自动备份方法

注意:请在设置前察看D:\\AEMS\\md\\andb\ablescript目录下是否有_anpmcatagory.sql这个文件,如果有此文件,则需要更改此文件名为_anpmcategory.sql,然后再开始设置 1) 将backupdbdata.bat、GenBKScript.exe两文件(具体文件请到技术支持网站的软件下

载中下载)复制到D:\\AEMS\\md\\andb\\dbbackupdata目录中。

2) 将backupdb.bat文件(具体文件请到技术支持网站的软件下载中下载)拷贝至

D:\\AEMS\\md\\bin目录中。

3) 点击桌面“开始”菜单—“设置”—“控制面板”。 4) 在控制面板界面中选择“任务计划”。 5) 选择“添加任务计划”。

6) 在任务计划向导程序界面中,选择“下一步”。

7) 点击“浏览”,

8) 在程序浏览窗口,选择D:\\AEMS\\md\\bin\\backupdb.bat文件并点击打开。

9) 在如下图窗口中,填入相应的任务名称,并设置执行此任务的间隔。

注意:由于自动生成的备份目录为系统的年月日,故计划任务不要设置成一天会运行几次,当同一天运行第二次的时候会提示是否覆盖已存在的文件,这样就要人工干预,故一般设置为每天、每周或者每月,不要设置为其它的选项。 10) 在如下图窗口中选择任务计划执行的起始时间。

11) 在如下图窗口中输入执行此任务计划的用户名和密码,请在“输入用户名”项务必输入

“主机名\\系统用户名” 用户(此处主机名为数据库所在服务器的机器名,本图主机名以STP-YDLI-A为例;系统用户名为当前登录windows系统的用户名,本图以informix为例)以及与之相对应的密码!

12) 点击“完成”按钮即可。

13) 在任务计划窗口会出现新的一条名为“backupdb”的任务,对其点右键选择“运行”,

在状态项中没有出错提示的情况下,查看e:\\backup\\目录中按当前日期生成的网管配置文件,即表示任务设置成功。

2. ANM2000手动恢复备份方法

由于自动备份时是备份的数据库中的表格数据,与网管中导出配置数据是不一样的,不能通过导入配置数据的方法把备份文件导入数据库,故需采用如下方法导入配置数据。 1) 打开“开始”—“程序”—“informix”—“sql editor 3.01”,连接本机的数据库

“andb@ol_***”,如下图:

2) 点击sql editor 3.01窗口菜单中的“file”—“open”,打开

D:\\AEMS\\md\\andb\\dbbackupdata目录下的“nImportDB.sql”文件,如下图:

3) 点击sql editor 3.01窗口菜单中的“SQL”—“execute all sql”,运行导入文件的

sql语言,执行后没有错误提示则表示导入成功。

附件:

backupdb.bat文件说明:

用“记事本”将此文件打开显示为: @set dd=%date:~0,10%

mkdir e:\\backup\\%dd%\\dbbackup ---------------------备份的配置文件保存目录 cd /d D:\\AEMS\\md\\andb\\dbbackupdata call backupdbdata.bat

xcopy D:\\AEMS\\md\\andb\\dbbackupdata\\*.* e:\\backup\\%dd%\\dbbackup\\ /-y --------将备份的配置文件自动拷贝至已建立的备份配置文件保存目录

八、服务器与客户端连接有IP转换时的特殊配置

注意:以下所说的\"服务器数据库网卡ip\"指的是网卡的实际ip,而\"服务器经过防火墙转换后的ip\"指的是经过NAT转换之后的ip。

如果服务器IP经由防火墙NAT转换,再以转换后的IP与客户端相连的组网,这种场景下想在客户端打开网管界面,需要确认如下配置:

1、客户端安装时连接的ip为服务器经过防火墙转换后的ip;

2、服务器的fhanms/aems.ini配置文件中以下位置新增一个参数: [BROWSER]

USE_GUI_DATABASE_PARAMETER=1

3、服务器的fhanms/aems.ini中修改:DATABASE_CONNECT_IP = \"服务器数据库网卡ip\"

4、服务器的md.ini中修改:DATABASE_CONNECT_IP = \"服务器经过防火墙转换后的ip\"

再重新打开界面即可!

九、网管服务器informix,anm2000的密码修改步骤

1) 确认网管为930版本及其后续版本均可以修改用户名或者密码,现把修改密码方法整理

出来,用户名类似。

2) 暂停所有网管数据库相关服务。

3) 在我们电脑---管理---本地用户和组,点击相关用户修改其密码。

4) 启动数据库服务。点击实例----属性---登录,选择用户并且修改其密码,如下图:

5) 进入aems\\md\\ini目录下,修改md.ini密码,如下图。

6) 进入aems\\fhaems\\ini目录下,修改aems.ini密码,如下图。

7) 重启服务或者电脑。

其他

一、电脑无法抓到数据VLAN信息处理方法

某一些网卡驱动默认会在接收数据包的时候过滤vlan tag,使得用wireshark抓到的数据包中不含vlan tag,此时需要通过修改注册表让驱动保留vlan tag。

1、 对于Intel PRO/1000或PRO/100网卡,需要将注册表

HKEY_LOCAL_MACHINE\\SYSTEM\\ControlSet001\\Control\\Class\\{4D36E972-E325-11CE-BFC1-08002BE10318}\\00xx下的MonitorModeEnabled改为1,如果不存在则新建这么一个dword键。

注意:在注册表中有很多00xx,需要找到电脑的网卡所在的00xx,然后在这个00xx下添加以上键值,例如我的电脑是0010

2、 对于Broadcom千兆网卡,需要在注册表里增加一项PreserveVlanInfoInRxPacket=1,类

型为string。位置与TxCoalescingTicks相同,后者可以在

HKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet下搜索到。

因篇幅问题不能全部显示,请点此查看更多更全内容